Signs Your Radon System Has Stopped Protecting You
A radon system works quietly, which is exactly why a failure can go unnoticed for months. The fan sits in the attic or on the side of the house, and the only everyday sign it’s working is a small U-tube gauge on the basement pipe. When that gauge goes flat, radon starts building back up. In Polk County, where untreated homes average roughly 7.3 to 9.2 pCi/L, that can push your level well past the 4.0 action line without any smell or symptom to warn you.
Watch for these signs:
- The liquid in your manometer is level on both sides.
- The fan has gone silent, or the hum turned into a rattle or grind.
- An electronic radon alarm is beeping or showing an error code.
- Ice is building at the top of an exterior pipe.
- Water is dripping from a joint or around the roof flashing.
Radon Systems of Iowa handles radon system repair in Altoona and nearby towns, and it doesn’t matter who installed your system. If you don’t have one yet, start with radon mitigation.
Quick Checks Before You Call
Some “failures” are a tripped breaker. Before booking a visit, take two minutes:
- Check the breaker that feeds the fan circuit.
- Check the disconnect switch mounted near the fan. Someone may have switched it off during other work.
- Listen at the fan. A steady hum means it’s running. Silence or grinding tells us a lot.
- Snap a photo of the manometer and the fan label.
If the breaker and switch are on and the gauge is still level, it’s time for a professional. Fans are sealed units, and pipe work above the roofline isn’t a ladder job most homeowners should take on. Call us with your photos and we’ll usually tell you the likely cause, and the price, before we arrive.
Reading the U-Tube Gauge
The manometer measures suction in inches of water column, not radon itself. It tells you whether the fan is pulling, not what your radon level is.
| Manometer Reading | System Status | Required Action |
|---|---|---|
| 0 inches WC (levels are even) | Fan is off, failed or a pipe has separated. | Check the breaker and disconnect switch, then call for service. |
| 0.5 to 1.75 inches WC | Typical operating suction for many homes. | No action needed. Note the level so you notice changes. |
| Above 2.0 inches WC | Fan is working hard, possibly against a blockage. | Watch for new noises, ice or moisture and have it checked. |
Your system’s normal reading may differ from these ranges. What matters most is change. Our guide on what a zero manometer reading means also covers electronic alarms and error codes.
Repairs We Make Most Often
Dead or dying fans
Fan failure is the most common call we get. These motors run every hour of every day, and moisture and heat take a toll. Sometimes a thermal protector shuts the fan off when it overheats. Quality fans often last 7 to 10 years, so an older system may simply be due. We confirm the cause before recommending a replacement. See how long a radon fan lasts.
Rattles, buzzing and vibration
A soft hum is normal. Rattling usually comes from a loose rubber coupling or a fan mounted hard against framing. Grinding points to bearing wear, often from moisture that collected after the fan was switched off. Isolators, tightened couplings or a small relocation usually solve it. More in radon fan noise causes and fixes.
Cracked pipe, loose joints and roof leaks
Freeze-thaw cycles crack PVC over time, sagging hangers let water pool, and roof boots wear out. A crack inside the house is the worst case, because it can draw soil gas into your living space. We replace damaged sections, re-seal every joint and fix flashing so the system holds suction again.
Alarms and error codes
Electronic monitors flag problems the U-tube can’t. Many alarms trace back to a stopped fan or a lost connection, and others mean a sensor needs service. Note the code before you call.
Winter Freeze-Ups and Frost Damage
Central Iowa winters are hard on exterior systems. January lows often sit in the teens, and warm, moist soil gas meets frigid air right at the outlet. Condensation turns to ice, the outlet narrows, and eventually the fan can’t push air out. Around Altoona, we see these calls spike every cold snap. The fix is usually a combination of correcting the pipe slope so water drains back, adjusting outlet size or adding a condensation bypass. In some homes, rerouting the pipe through the garage and attic solves the problem for good and looks better too. Read more about winter radon pipe problems.
Fixing Systems Another Company Installed
Plenty of the systems we service were installed by someone else, sometimes a company that no longer exists. In established areas like Northview Heights, we often find older systems with an open sump nearby, unsealed block walls or a pipe that was never labeled. We’ll repair what failed and tell you honestly whether a design upgrade, like a sealed sump lid or an added suction point, would make a real difference. You decide what to do. We also upgrade builder-installed passive pipes in newer homes by adding a fan.
Repair Pricing and the Follow-Up
We quote the repair once we know what failed. Price depends on the part, where the fan is mounted and whether winter damage is involved. A targeted repair is usually far less than installing a new system. After the work, we confirm the manometer shows suction, inspect the disconnect switch and wiring and check couplings for vibration. If the fan was off for weeks, we recommend a radon test so you know your level is back where it belongs.
Our specialists repair radon systems seven days a week across Altoona, Pleasant Hill, Bondurant, Mitchellville and the Des Moines east side. Call (515) 782-6070 and describe what you’re seeing.